Current Situation
  • Majority of the ENCON schemes presented by AOTS/EECJ/JCCP (Referring directory of energy conservation tech in Japan’2006) are already in place in many Indian Refineries
  • Some of the schemes not applicable due to non-existence of units (e.g. Reduction of O2 content in Flue gas in heavy oil direct desulphurization unit)

DESIGN SCHEMES IMPLEMENTED IN SOME OF NEW INDIAN REFINERIES FROM THE DIRECTORY OF ENERGY CONSERVATION , JAPAN.
    OR-ME-1 (SCHEME FOR REDUCTION OFVACUUM COLUMN STRIPPING STEAM BY RECYCLING OVERHEAD STEAM)
    THIS SCHEME HAS BEEN IMPLEMENTED IN PUNJAB REFINERY PROJECT, BATHINDA, INDIA.
    IT HAS BEEN ESTILATED THAT FOR ONE OF THE DESIGN CRUDE CASES, THE STRIPPING STEAM REQUIREMENT WOUL REDUCE BY APPROX 4200 KG/HR , BASED ON MP STEAM PRICE OF Rs 702 /MT, THE SAVINGS WOULD BE ABOUT 2.35 CR/ANNUM
    PAYBACK PERIOD IS 1 YEAR.