AEEC Home | Training Index | Index | Top | Previous | Next

METI / ECCJ / ACE Training Program MTPEC04 (2006.02)

Simple Energy Audit
Week Point of Detail Audit:
It needs much resources (man power, time, measurement, etc), compared tobenefit.
Simple Audit:
Omit time-consuming step (heat & material balance step)
Look at check-points shown as following;
Check-points in Simple Audit:
Dryer : exhaust gas temp ... potential of heat recovery
humidity ... potential of high-temp/high-humid drying
Hot air furnace : stack gas temp ... potential of heat recovery
O2 ... potential of excess air reduction
Insulation : surface temperature ... potential of heat loss reduction
Fan : damper opening, %load, motor kW ... potential of inverter control
Dust collector : P ... potential of fan power saving

Audit Example in Turkey:
(Sanitary Paper Factory)

61/85
Next
AEEC Home | Training Index | Index | Top | Previous | Next
Copyright(C) ECCJ 1996-2019