General administrative matter
- Energy management system
- Organization improvement, human resource development
- Energy conservation target, investment budget
- Setting of management standards
- State of implementation of energy conservation
- State of implementation of measurement / recording
- State of installation and operation of measuring instruments
- State of maintenance, inspection of measuring instruments
- State of implementation of periodic measurements and recording
- State of introduction of measurement and control systems
- Management of energy consumption
- State of keeping daily reports
- Daily consumption, daily load variation curves
- Monthly consumption
- Graph for the ratio to the consumption of the receding year
- State of facility and equipment maintenance
- Periodic inspection, routine inspection
- Management of facility performance , coefficient of performance (COP)
- Management of system performance (COP)
- Facility and equipment cleaning (filter, strainer)
- Energy unit consumption management
- Heating value unit consumption (MJ/m2 year)
- Energy cost unit consumption (1,000 yen/m2 year)
- Unit consumption by use of building
- Unit consumption by consuming end
- Plan-do-check-action (PDCA) management circle
- State of implementation of PDCA management
- State of implementation of continual improvement
Heat source, heat transfer facility
- Management of combustion facility performance
- Air ratio, exhaust gas management
- Burner, fuel, air supply system
- Combustion control system
- Fuel conversion (boiler, generator, etc.)
- Management of refrigerator performance
- Coefficient of performance (COP)
- Setting of cooled water outlet temperature
- Setting of cooling water temperature
- Removal of scale from heat exchangers
- Temperature efficiency ratio of heat exchangers
- Operation management, efficiency management
- Load factor, state of startup and shutdown
- Start and stop control
- Thermal efficiency, heat balance, heat distribution
- Steam pressure
- Water quality control, blowing operation control
- Operation management of auxiliary facilities
- Operation control of cooling towers
- Water quality control (electrical conductivity)
- Operation control of pumps (capacity, head)
- Improvement of routes
- Operation management of heat carrier facilities
- Start and stop control of pumps, fans
- Rotation control of pumps, fans
- Improvement of routes (open, closed)
- Flow rate, pressure
- State of opening and closing of valves (automatic valve, header bypass valve, etc.)
- Exhaust gas temperature, recovery of waste heat
- Exhaust gas temperature control
- Heat recovery (HP, CGS, etc.)
- Management of steam leaks / insulation
- Piping system
- Facility with steam load
- Management of heat storage; heat storage efficiency
- Heat storage, heat liberation time
- Improvement of heat carry routes
|