AEEC Home | Training Index | Index | Top | Previous | Next

ECCJ / Text Thailand

4.17 Example of the Required Power of Screw Type Compressor

4.18 Compressor Number Control in Operation (Example)

5. Energy Conservation Cases

5.1 Stopping when unnecessary

5.1.1

  • Reduction of unnecessary power consumption by a power consumption identification and measurement system
    Cimx Corporation
    Successful cases in FY2005 Director General Prize of Agency of Natural Resources and Energy


    • Overview of this establishment
      - Production items: Die manufacturing, software development
      - Number of employees: 48
      - Annual energy consumption (Actual record in April 2004-March 2005): Electricity 698,904kWh

      Theme Overview
      For small and medium-sized enterprises that are making bloody efforts to reduce cost, electricity expense, which is “unexplained expenditure” because it is unclear when, for what, and how much of it was used, is a heavy burden.

      By clarifying the use of the electricity, it can be can identified whether electric energy is used in a really valiant way or not.

      In production factories, the more the production volume, the more energy is consumed. Therefore, we consider that it is more important to identify and zero waste than to control total volume.

      To realize this, we have created a system to measure electric power consumption for each electric facility and identify whether it is necessary or not.

      By visualizing the information obtained from the system and give feedback to all the corporate members, we worked on reduction of unnecessary electric power consumption in daily business operation.

17/24
Next
AEEC Home | Training Index | Index | Top | Previous | Next

Copyright(C) ECCJ 1996-2019