AEEC Home | Training Index | Index | Top | Previous | Next

METI/ECCJ/AOTS Training Program Vietnam

Periodical Report
Item
Description
Remarks
Obligation to submit periodical reports Class 1 designated factories Which comes in 2 types of heat and electricity May every year
Information contained in the report (for heat) Fuel consumption Unit: kl/year of crude oil equivalent
Overview of principal equipment items, Operating status, Modifications, and Similar information Equipment that consumes 100 kl more of crude oil annually
Production volume Added value production amount in monetary terms (ex. Production amount – material cost) may also be entered
Fuel intensity  
Reasons why it has been impossible to improve fuel intensity 1% or more To show reasons, including declines in product prices, change in production structure, and other such factors
Level of compliance with the judgment criteria  
Other energy conservation measures  

Medium-and Long-term Plan
Item
Description
Remarks
Obligation to submit plans Class 1 designated factories May every year
Applicable equipment Combustion equipment, Heat utilization equipment , Waste heat recovery equipment, Co-generation systems, Electricity utilization equipment, Air-conditioning equipment, Lighting equipment, Excess air utilization equipment, Unused energy utilization equipment Notification (of February 25, 1999) by the Finance Ministry, etc.
Information contained in the report (for heat) Period of plan 3 to 5 years as a guide
Details of the plan and the expected effect Name of equipment, Number of units, Specific implementation items
Comparisons with the plan for the preceding year Reasons for changes in the plan
Other related items  

Regulations regarding buildings
(newly built, extended)
 
  1. Obligations to building owner
    • Prevention of heat loss through external walls and
      windows.
    • Efficient utilization of energy for air conditioners,
      ventilation systems, lighting, water heaters, elevators.
    • Owners of specified buildings should report on energy saving
      measures before the construction.
      (specified buildings : other than housings, with floor space of 2,000m2 or more)
    This article was added and enforced in April 2003 ECCJ
  2. Guidance and standards for the building owners on building design and construction.

Energy Efficiency Standard for Appliances and Automobiles
Top Runner Program –Concept–

9/33
Next
AEEC Home | Training Index | Index | Top | Previous | Next
Copyright(C) ECCJ 1996-2019