AEEC Home | Training Index | Index | Top | Previous | Next

ECCJ / Text Thailand

Attachment Table 1 (A) Base air ratios (I 1 (1) 2))
(2) Base air ratios for industrial furnaces (I 1 (1) 2))
(2) Base air ratios for industrial furnaces (I 1 (1) 2))

  • Notes:
    1. Values for base air ratio given in this table are for the air ratio measured at the furnace exhaust outlet at combustion at near rated load after inspection or repair.
    2. The value for liquid fuel shall be used for the air ratio of industrial furnaces combusting blast furnace gas or other byproduct gas.
    3. The base air ratios given in the table shall not apply to the air ratios of the following industrial furnaces:
      • (1) Furnaces using solid fuel, excluding single-fuel furnaces fueled by powdered coal.
      • (2) Furnaces with a rated capacity (burner fuel combustion performance) of under 20 L per hour (fuel equivalent).
      • (3) Furnaces requiring a special atmosphere for oxidation or reduction.
      • (4) Furnaces requiring dilution air for heat pattern maintenance or equalization of internal temperature.
      • (5) Furnaces combusting byproduct gas with a heat value of not more than 3,800 kJ per normal cubic meter.
      • (6) Furnaces not in operation at regular inspection or otherwise not in regular use, and furnaces used for development, research, or trial production.
      • (7) Industrial furnaces using materials that degenerate at high temperature and requiring air for cooling dilution.
      • (8) Furnaces combusting combustible waste.

20/29
Next
AEEC Home | Training Index | Index | Top | Previous | Next

Copyright(C) ECCJ 1996-2019