Attachment Table 1(B) Target air ratios (II 1 (1) 1))

(1)Target air ratios for boilers
(1)Target air ratios for boilers

  • * For electricity supply business means facilities installed by electricity suppliers to generate electricity.

  • Notes:
    1. Values for target air ratio given in this table are for the air ratio at the boiler outlet at combustion at a fixed load under stable conditions after regular inspection.
    2. Load factor and air ratio are calculated based on Notes 2 and 3 to Attachment Table 1 (A) (1).
    3. The target air ratio for solid fuel fixed-bed boilers fueled by powdered coal shall be 1.15-1.25 for electricity supply business, and 1.2-125 for other (provided that such facilities have an evaporation capacity of from 30 tons per hour or from 10 tons to under 30 tons.
    4. The value of the target air ratio for boilers combusting black liquor shall be 1.2-1.3 at a load factor of 50-100%.
    5. For multifuel boilers combusting multiple types of fuel, the target air ratio for the fuel with the highest fuel ratio, based on heat value, shall apply.
    6. Values for target heat value given in the table shall not apply to the air ratios of the following boilers; provided, however, that consideration shall be given to control of the air ratio based on the table where possible:
      • (1) Small boilers provided for in Article 1.4 of the Occupational Safety and Health Law Enforcement Ordinance.
      • (2) Boilers modified after installation for fuel conversion.
      • (3) Multifuel boilers combusting wood waste, tree bark, sludge, and other industrial waste with fuel.
      • (4) Boilers combusting waste tires.
      • (5) Furnaces combusting byproduct gas with a heat value of not more than 3,800 kJ per normal cubic meter.
      • (6) Boilers processing toxic gas.
      • (7) Boilers using waste heat.
      • (8) Boilers not in operation at regular inspection or otherwise not in regular operation, and boilers used for development, research or trial production.